Move tile batches between process lines and hold planned work-in-process without treating every pause as the same buffer problem. BASAIR receives the line duty, layout and production constraints; the partner confirms the transfer mechanism, storage arrangement, controls and final supply boundary for the project.
1. Separate transfer duty from storage duty
A transfer unit changes the location of a tile stack or batch between defined infeed and outfeed points. A storage line holds multiple batches so production can continue across a planned sequence, a format change or a downstream interruption. Define both duties before choosing equipment: the same project may need a compact transfer station, a multi-lane storage area, or the two connected as one controlled system.
This page covers line-to-line transfer and temporary batch storage. It does not replace tile loading and unloading selection, general conveyor and positioning design, or a short-duration line buffer and accumulator.

2. Make the main selection trade-offs explicit
| Decision | Choose the first direction when | Choose the second direction when | Confirm before quotation |
|---|---|---|---|
| Transfer only vs. transfer plus storage | The next process is continuously available and only the route changes | Batches must wait, be sequenced or be isolated during a downstream stop | Stop scenarios, required hold time and restart sequence |
| First-in/first-out vs. flexible retrieval | Product sequence must remain unchanged | Orders or formats may need controlled resequencing | Batch identity, recipe logic and permitted reordering |
| Surface-mounted vs. pit-integrated conveying | Civil work must be minimized and floor crossings are manageable | A flush interface or lower transfer elevation justifies civil work | Floor loading, pit dimensions, drainage and maintenance access |
| Compact lanes vs. higher batch capacity | Available footprint is the binding constraint | Longer hold time and format separation have priority | Usable area, clear height, aisle access and batch count |
3. Use source numbers as configuration references, not promises
On the cited transfer-system reference configuration, the partner page lists 1.5 kW and 2.3 kW figures for robot motions, a two-belt infeed driven by a 1.1 kW motor with variable-frequency speed control, and an approximately 7 m plate-chain conveyor with 1.5 kW installed power. It also describes servo and worm-reducer drives, electronic and mechanical travel limits, and a large-stroke pneumatic cylinder for pushing an empty tile frame into position.
Those values describe that cited arrangement only. The selected motor power, travel, conveyor length, transfer height, storage capacity and cycle time depend on stack mass, tile dimensions, direction of travel, batch logic, safety layout and the upstream/downstream equipment confirmed for the project.

4. Freeze every mechanical, control and safety interface
- Product: tile material and finish, length, width, thickness, unit and batch mass, stack height, separator or frame, edge condition and permissible contact areas.
- Line geometry: infeed and outfeed directions, datum side, conveyor elevation, lane spacing, transfer stroke, turning restrictions, floor area and clear height.
- Mechanical and civil: support points, frame or pallet dimensions, floor loading, anchor plan, any pit, drainage, guarding footprint and maintenance-removal route.
- Electrical and pneumatic: site voltage and frequency, available connected load, compressed-air pressure and quality, cable/air entry and isolation points.
- Controls: upstream/downstream ready, run, blocked, full, empty and fault signals; batch identification; recipe ownership; recovery after power loss; manual and maintenance modes.
- Safety: risk assessment, fixed and interlocked guarding, safe access, emergency-stop zoning, travel limits, presence detection, stored-energy isolation and responsibility for site compliance.
- Acceptance: agreed tile and batch set, transfer sequence, storage/retrieval logic, fault-recovery trials and measurable handover conditions.
BASAIR coordinates the buyer’s duty and line interfaces. The partner confirms the final mechanism, engineering values, guarding, controls and deliverables before an offer is frozen.
5. Submit the data needed to size the system
| Submission item | Minimum detail | Why it matters |
|---|---|---|
| Tiles and batches | Material, surface, size range, thickness, unit mass, tiles per batch, stack/frame photos | Sets support, contact, load and travel requirements |
| Production duty | Current and target rate, shifts, format mix, batch sequence and planned time | Sets cycle and recipe requirements |
| Storage case | Stop scenario, required hold time, maximum batches, FIFO/retrieval rule | Determines capacity and lane logic |
| Existing line | Layout, elevations, directions, machine drawings, signals and available space | Defines the physical and control handoff |
| Utilities and safety | Power, air, floor/pit constraints, local safety requirements and responsible parties | Prevents an incomplete supply boundary |
For the wider line path, review automation, handling and packaging and the tile automation and packaging solution.
Submit your transfer path, batch data and layout for configuration review
Choose between pushing, mobile transfer and a fixed handoff
A push-off station moves a supported batch from one defined position; a mobile transfer unit changes the position of the handling carriage; a double-layer arrangement introduces separate upper and lower transfer references. These routes solve different layout problems. Provide both handoff heights, the loaded and empty return paths, stack restraint, maximum batch mass and the space needed to recover a stopped batch. A transfer machine does not automatically provide batch storage or controlled resequencing.